Com-Power’s power injector probes are utilized for RF conductivity tests according to IEC 61000-4-6, CISPR 16-1-2, RTCA DO-160, and MIL-STD 461 standards. When suitable Coupling Decoupling Networks (CDN) are not available for the port under test, these power injectors are employed in conjunction with spectrum analyzers or EMI receivers. This method involves injecting a significant amount of RF current into a cable instead of directly onto a port.
The CLCI-100 and CLCI-400 models are constructed with split-core ferrites in a sturdy hinged enclosure, combining durability and convenience.
The CLCI-100 operates within a frequency range of 10 kHz to 100 MHz and meets the requirements of IEC 61000-4-6. On the other hand, the CLCI-400 covers a frequency range of 10 kHz to 400 MHz and complies with MIL-STD-461 and RTCA DO-160 standards.
A calibration fixture is available separately.